And why would it fail?
The main safety features (longer/bigger earth pin, base insulation on the others, cable enters from bottom, fingers kept away from pins, holds firm in socket, fuse) are all kept.
I can't quite see how the neutral and live pins are wired/seperated, but even if that gets fucked up you just blow the fuse.
(, Wed 24 Jun 2009, 16:13, Reply)
Touch them and the fuse goes. Wire them up backwards and you might as well just swap the fuse for a bolt for all the good it will do.
(, Wed 24 Jun 2009, 22:06, Reply)
sorry but i'm a sparks and reverse polarity will not affect the normal operation of the majority of electrical equipment but will make it bloody dangerous as switching off an isolator will not turn off the power coming in to the equipment
(, Thu 25 Jun 2009, 12:23, Reply)